Share:


INVERTEK DRIVES OPTIDRIVE CoolVert Series

Support various customization

01 200 – 240V ± 10% 1 Phase Input

Checklist

- CV-220070-1F#P

- CV-220120-1F#P

- CV-220160-1F#P

- CV-220200-1F#P

02 380 – 480V ± 10% 3 Phase Input

Checklist

- CV-240140-3F#E

- CV-240180-3F#E

- CV-240240-3F#E

- CV-340300-3F#E

- CV-340390-3F#E

- CV-440460-3F#E

- CV-440580-3F#E

- CV-540650-3F#E

- CV-540750-3F#E

High Performance Drive Specifically for BLDC Compressors, Heat Pumps & CDUs

Invertek’s high-performance OPTIDRIVE™ CoolVert; designed specifically for machine builders to optimise the performance of BLDC compressors used in Heat Pumps and Condensing Units (CDUs), improving overall system performance and lowering energy costs.

Features:
1. Open Connectivity & Easy Commissioning
  • Seamless connectivity with any application controller
  • Built in RS485 Modbus RTU
  • Bluetooth connectivity available via Optistick Smart
  • External TFT keypad available
  • Drive status LEDs
2. Environmental
  • Compact design with through panel mounting
  • Wide operating temperature: −20˚C to 60˚C
  • IP20 rated front enclosure, IP55 at the rear
  • Coldplate version available
  • Coated PCBs meet class 3C2 in accordance with EN60713-303
  • Built-in EMC filter class C1 in accordance with EN61800-3-2004
  • Low harmonic design compliant with; EN61000-3-2, (1 phase 200-230V input), and EN61000-3-12, (3 phase 380-480V input).
3. Supply voltages and output current range
  • 1 x 200–240V (± 10%): 7.0A, 12A, 16A, 20A All single phase drives with active PFC
  • 3 x 380–480V (± 10%): 14A, 18A, 24A
4. Selectable motor types
  • AC Induction (IM)
  • AC Permanent Magnet (PM)
  • Brushless DC (BLDC),
  • Synchronous Reluctance (SynRM)
  • Line Start Permanent Magnet (LSPM)
5. Control Terminals
  • Pluggable control and communication terminals
  • STO SIL3 Safe Torque Off for system protection, TUV approved
  • Programmable, predefined input and output functions:
  • Start / Stop (Enable / Disable)
  • PTC motor thermal protection (0-10V, 4-20mA)
  • Relay (drive healthy / trip)
6. Through Panel Mounting
  • Reduces panel size
  • Improves thermal management
  • Supports improved IP ratings for electronics
  • Cold-plate version also available

7. Safe Torque Off (STO)
  • Lower Harmonics compliant with:
  • EN 61000-3-2: 1-phase Input Drives
  • EN 61000-3-12: 3-phase Input Drives

Technical Specifications:
Input Ratings
 
Supply Voltage
 
200 – 240V ± 10%
380 – 480V ± 10%
Supply Frequency 48 – 62Hz
Displacement Power Factor > 0.98
Phase Imbalance 3% Maximum allowed
Inrush Current < rated current
Output Ratings
 
Output Power
 
200V: 7.0A to 20A
400V: 14A to 75A
Overload Capacity 130% rated current for 10s
Output Frequency 0 – 500Hz
Acceleration Time 0.01 – 600 seconds
Deceleration Time 0.01 – 600 seconds
Typical Efficiency > 98%
Ambient Conditions Temperature
 
Storage: -40 to 60°C
Operating: -20 to 50°C
Altitude
 
Up to 1000m ASL without derating
Up to 2000m maximum
Humidity 95% Max, non condensing
Vibration Conforms to EN61800-5-1
Enclosure Ingress Protection Front IP20
Rear (Through Panel Mounting) IP55
Coated PCBs Designed for operation in 3S2/3C2
environments according to IEC 60721-3-3
Programming Modbus RTU
(RS485)
Modbus RTU / CAN through terminals and RJ45 port.
PC Tools PC Tools software for Diagnostics and
parameter configuration (RJ45 port only).
Keypad Optional Remote Keypad with TFT display for diagnostic and programming
Smartphone app Optitools Mobile
Control Specification
 
Control Method
 
Modbus RTU (RS485)
Terminal Control Digital / Analogue
Terminal Control PI mode
Master / Slave Mode
PWM Frequency 4 – 32kHz
Stopping Mode Ramp to stop, Coast to stop
Control Modes Modbus RTU (RS485)
Terminal Control Digital / Analogue
Terminal Control PI mode
Master / Slave Mode
Skip Frequency 2 skip frequencies, user adjustable
Safe Torque Off (STO) IEC 61800-5-2:2016 SIL 3
UL 61800-5-2 : 2022 SIL 3
Independent Approval TUV Rheinland / UL


 Inquiry - INVERTEK DRIVES OPTIDRIVE CoolVert Series