Share:


INVERTEK DRIVES Optidrive Compact 2 Series

Support various customization

01 110 – 115V ± 10% 1 Phase Input

Checklist

- OPC-2- 110023-1E1G003K

- OPC-2- 110032-1E12003K

02 200 – 240 ± 10% 1 Phase Input

Checklist

- OPC-2- 120023-1E1G003K

- OPC-2- 120043-1E12003K

- OPC-2- 120070-1E12003K

03 200 – 240 ± 10% 3 Phase Input

Checklist

- OPC-2- 120023-3E1GH03K

- OPC-2- 120043-3E1GH03K

- OPC-2- 120070-3E12H03K

04 380 – 480 ± 10% 3 Phase Input

Checklist

- OPC-2- 140022-3E1GH03K

- OPC-2- 140041-3E12H03K

- OPC-2- 240058-3E4GHS3K

- OPC-2- 240095-3E4GHS3K

05 PFC 110-230V +/-10% Single Phase Input

Checklist

- OPC-2- 110043-1F1GPS3K

06 PFC 200-240V +/-10% Single Phase Input

Checklist

- OPC-2- 110070-1F1GPS3K

The OPTIDRIVE Compact 2 is offered in both Basic and Advanced variants. The main differences between the models is I/O including STO and the parameter set. Both models can be tailored to OEM requirements dependent on the application and the quantities of drive required for the project. The parameters used in the Basic version are suitable for simple applications such as fans, pumps and conveyors.  The parameters used in the Advanced version are more suitable for advanced machine control applications.

Features:                                          
1. Open Connectivity Easy Commissioning
  • Seamless connectivity with any application controller
  • Built in RS485 Modbus RTU
  • Bluetooth connectivity available via Optistick Smart
  • External TFT keypad available
  • Drive status LEDs
  • Communications options; Ethernet & Modbus TCP size 2 only
2. Environmental
  • Wide operating temperature: −10˚C to 50˚C
  • IP20 rated front enclosure
  • Cold plate mounting for inclusion into OEM machnines
  • Coated PCBs meet class 3C2 in accordance with EN60713-303
  • Built-in EMC filter class C2 in accordance with EN61800-3-2004
  • Low harmonic design compliant with; EN61000-3-2, (1 phase 200-230V input), and EN61000-3-12, (3 phase 380-480V input). Model dependent.
3. Selectable motor types
  • AC Induction (IM)
  • AC Permanent Magnet (PM)
  • Brushless DC (BLDC),
  • Synchronous Reluctance (SynRM)
  • Line Start Permanent Magnet (LSPM)
4. Control Terminals
  • Pluggable communication terminals
  • Fixed spring loaded input terminal for easy installation
  • STO SIL3 Safe Torque Off for system protection
  • Programmable, predefined input and output functions:
    • Start / Stop (Enable / Disable)
    • PTC motor thermal protection (0-10V, 4-20mA)
    • Relay (drive healthy / trip)

Supply voltages & output current
  • 1 x 110 -115 +/-10% 230 V output 2.3A & 3.2A
  • 1 x 200 -240V +/- 10% 230 V output 2.3A, 4.3A & 7A
  • 3 x 200 -240V +/- 10% 230 V output 2.3A, 4.3A & 7A
  • 3 x 380 - 480V +/- 10% 480 V output 2.2A, 4.1A, 5.8A & 9.5A

Active PFC Units
  • 1 x 110 -230V +-10% 230V output 4.3A
  • 1 x 200 -230V +/- 10% 230 V output
Technical Specifications:
Input Ratings
 
Supply Voltage
 
110 -115V +/-10%
110-230V +10% -20%
200 -240V +/-10%
380 - 480V +/- 10%
Supply Frequency 48 – 62Hz
Displacement Power Factor > 0.98
Phase Imbalance 3% Maximum allowed
Inrush Current < rated current
Power Cycles 120 per hour maximum, evenly spaced
Output Ratings
 
Output Power
 
110 -115V 0.37-0.75kW
110-230V 0.75kW
200 -240V 0.37-2.2kW
380 - 480V 0.75-5.5kW
Overload Capacity 150% for 60 Sec
*200 V 3 & single phase input 7 A units 110%
overload.
Output Frequency 0 – 500Hz, 0.1Hz resolution
Acceleration Time 0.01 – 600 seconds
Deceleration Time 0.01 – 600 seconds
Typical Efficiency > 98%
Ambient Conditions Temperature
 
Storage: -40 to 60°C
Operating: -10 to 50°C
Altitude
 
Up to 1000m ASL without derating
Up to 2000m maximum UL approved
Up to 4000m maximum (non UL)
Humidity 95% Max, non condensing
Vibration Conforms to EN61800-5-1
Enclosure Ingress Protection IP20
Coated PCBs Designed for operation in 3S2/3C2
environments according to IEC 60721-3-3
Programming Modbus RTU
(RS485)
Modbus RTU / CAN through terminals and
RJ45 port.
PC Tools PC Tools software for Diagnostics and parameter configuration (RJ45 port only).
Function block programming via downloadable software (Advanced Version)
Keypad Optional Remote Keypad with TFT display for diagnostic and programming
Smartphone app Optitools Mobile
Control Specification
 
Control Method
 
Terminal
Comms
Terminal / Comms
PWM Frequency 4 – 32kHz Effective
Stopping Mode Ramp to stop, Coast to stop
Control Modes Modbus RTU (RS485)
Terminal Control Digital / Analogue
Terminal Control PI mode
Master / Slave Mode
Skip Frequency 2 skip frequencies, user adjustable
Application Features
 
PID Control Internal PID Controller
Intelligent
Drive Thermal
Management
Reduced-load operation of the system can be configured under high drive temperatures to prevent nuisance tripping
Intelligent
Motor Thermal
Management
Reduced-load operation of the system can be configured under continued motor overload to prevent nuisance tripping
Serial Communications-
Loss Fall-Back
Speed
The ability to configure the drive to run at a ‘safe’ speed in the even of a loss of serial communication. Can prevent total loss of operation whilst maintaining minimum process demands.
Master Follower
Configuration
The ability to run a cascade of machines with one Master regulating the operating point in PI Control


 Inquiry - INVERTEK DRIVES Optidrive Compact 2 Series